Target Recognition Triggered Split DNAzyme based Colorimetric Assay for Direct and Sensitive Methicillin-Resistance Analysis of Staphylococcus aureus
Department of Anesthesiology, People’s Hospital of Chongqing Liang Jiang New Area, Chongqing 401121, P.R. China
Correspondence to:J. Microbiol. Biotechnol. 2024; 34(6): 1322-1327
Published June 28, 2024 https://doi.org/10.4014/jmb.2404.04012
Copyright © The Korean Society for Microbiology and Biotechnology.
Abstract
Keywords
Graphical Abstract
Introduction
The infection in patients undergoing surgical treatment is mostly a nosocomial infection caused by bacteria, which not only exacerbates the patient’s suffering during treatment but also poses a significant cost burden.
The rapid and precise diagnosis of methicillin-resistant
Aptamers, referred to as chemical antibodies, are single-stranded DNA or RNA molecules that exhibit a strong and particular binding affinity for a diverse array of molecule [15]. These aptamers have found extensive application in the detection of the PBP2a protein, owing to their exceptional specificity and affinity towards the target molecules [16, 17]. Aptamers, in comparison to typical antibodies, exhibit greater stability and are more readily prepared and modified [18, 19]. This renders them viable substitutes for antibodies as recognition agents in
In the current study, an aptamer-based colorimetric biosensor was developed for the rapid, ultrasensitive, and visual detection of MRSA using recognizing probe and the split DNAzyme system. In this sensing strategy, an aptamer, which is integrated in the recognizing probe with loop-stem structure, was employed to specifically bind with PBP2a protein on the surface of
-
Fig. 1. The working mechanism of the proposed method for direct methicillin resistance analysis.
Materials and Methods
The sequences used in this method were synthesized and purified by Sangon Biotech (China). The detail of the sequences used in this research is shown in Table S1. The bacteria, including the methicillin-resistant
Detection Procedure of the Method
300 nM of the recognizing probe (10 μl) and various concentrations of MRSA (10 μl) were mixed in a tube containing 30 μl of PBS buffer. The mixture was incubated at room temperature for 30 min, followed by the mixing with the L probe@plate. Afterwards, 10 μL of the s1 and s2 sequences (100 nM, respectively) were added to the plate. The mixture was incubated at room temperature for 30 min. afterwards, the liquid supernatant was removed from the plate well, and the plate was washed for 3 times with PBS buffer solution. 10 μl of the LC and LR probe (100 nM, respectively), 20 μl of PBS buffer solution were added to the palte for the color reaction. Finally, 1 μl of hemin (20 μM, prepared in DMSO), 9 μl of 10 × HEPES (250 mM HEPES, 2 M NaCl, 100 mM KCl, and 0.5%Triton X-100, pH 5.2), and a sufficient amount of H2O were added to form a resultant solution of 90 μl, and then incubated for 30 min at 37°C. UV-vis absorption spectra were recorded at a fixed reaction time of 10 min after the addition of 10 μl of 4 mM ABTS2– and 10 μl of 400 mM H2O2 to the solutions.
Results and Discussion
Assembly of Recognizing Probe and Feasibility Analysis
A fluorescent assay was conducted to determine if the developed recognizing probe could selectively identify the target bacterium and subsequently mediate the proximity ligation of split DNAzyme. Fig. 2A demonstrates that the fluorescence intensity at 510 nm of the recognizing probe (R probe) was noticeably greater when incubated with the target compared to probes without the target. This indicates that the presence of bacteria can trigger the allosterism of the recognizing probe. To investigate the potential unfolding of a recognizing probe, various interfering molecules, including exosomes, protein A, MSSA (methicillin-sensitive
-
Fig. 2. Feasibility analysis of the proposed method.
(A) Fluorescence spectrum of the FAM labeled recognizing probe when MRSA exists or not. (B) Fluorescence intensities of the recognizing probe for target and interfering molecules detection. (C) Fluorescence intensities of the recognizing probe under different experimental conditions. (D) Fluorescence spectrum of the FAM labeled split DNAzyme before and after proximity ligation of split DNAzyme. (E) Fluorescence intensities of the FAM labeled LR probe during the catalytic hairpin assembly process. (F) Absorbance of the approach during MRSA detection. Inserted is the visible absorbance changes.
n = 3 technical duplicates.
Experimental Parameter Optimization
Prior to assessing the detection performance, we refined the experimental parameters of the approach, such as the concentration of the recognizing probe, the ratio of LC and LR probes, and the duration of the reactions. The Atarget/Ablank, which is the ratio of the absorbance when target existed (Atarget) or not (Ablank), is used to compare the detection performance of the method. In the studies examining the concentration of recognizing probes, the absorbance values obtained showed a gradual increase as the concentration of recognizing probes increased from 50 to 200 nM. However, no further increase in absorbance values was found at higher concentrations (Fig. 3A). Thus, the concentration of the recognizing probes was determined to be 200 nM. Furthermore, the proportion of LC and LR probes and the duration of the reaction were established as 1:1 (Fig. 3B) and 90 min (Fig. 3C), respectively.
-
Fig. 3. Optimization of experimental parameters.
Absorbance ratio of the approach when detecting MRSA with different R probe concentrations (A) concentration ratio of LC and LR probes (B) reaction time (C).
n = 3 technical duplicates.
Sensitive and Selectivity Detection of Methicillin Resistance S. aureus
The suggested colorimetric method was used to detect various quantities of MRSA N315 in PBS under optimized experimental conditions. To evaluate the capability of the established method for sensitive detection of MRSA, a range of target concentrations were prepared and examined. Fig. 4A displays the UV-vis absorption signals for different concentrations of the target. The absorbance consistently increased as the target concentrations ranged from 50 CFU/ml to 106 CFU/ml. Fig. 4B illustrates the linear relationship between the absorption intensities and the logarithm of the target concentration. The range of concentrations considered is from 50 CFU/ml to 106 CFU/ml. The linear correlation coefficient for this relationship is 0.9932. Based on the 3σ rule, the estimated detection limit is 23 CFU/ml, which above the detection limit of current approaches.
-
Fig. 4. Analytical performance of the method.
(A) Absorbance ratio of the approach when detecting MRSA with different concentrations. (B) Correlation between the absorbance ratio and the concentration of MRSA. (C) Absorbance of the approach when detecting MRSA and interfering bacteria.
n = 3 technical duplicates. (D) Absorbance of the approach when detecting MRSA from 10 sample duplicates.
The detection performance of a biosensor’s performance relies heavily on its selectivity. We employed three interfering bacteria to examine the discerning detection capability of the approach. The absorption intensities can clearly be distinguished of MRSA from MSSA,
Analytical Performance of the Approach
Target bacterial strains and MSSA strains were analyzed by colony counting method and the proposed method to evaluate the detection effect. The colony counting test results showed that 10 samples contained bacteria with methicillin resistance, which proved that 7 strains were MRSA, 3 strains were MSSA. The results of the proposed detection system also show the same result in all strains of bacteria such as 7 strains detected as MRSA, 3 strains were MSSA (Fig. 5A). The stability of the proposed method was assessed using 10% commercial whole blood supplemented with bacteria. As illustrated in Fig. 5B, by comparing the characteristic peak values, the recovery rates of the MRSA concentration calculated by the method ranged from 98.78% to 102.3%, indicating a high stability of the method in complicated experimental conditions.
-
Fig. 5. Clinical application of the method.
(A) MRSA positive sample reported by the method and colony counting method. (B) MRSA concentration calculated by the method from samples added with different concentrations of MRSA.
Conclusion
In this study, an aptamer-based colorimetric assay for MRSA detection was constructed based on the high affinity of aptamer to target protein PBP2a. In this method, the PBP2a protein aptamer is integrated in a recognizing probe with a hairpin structure. the specific target recognition leads to the allosterism of the recognizing probe, which provides a template for the proximity ligation of DNAzyme. The assembled DNAzyme cleaves the L probe on plate to induce subsequent signal amplification and color reaction. Eventually, the method exhibits a low limit of detection of 23 CFU/ml and high specificity towards MRSA compared to MSSA with potentials for rapid detection of MRSA in real clinical specimens, such as plasma. In addition, the total time of the method for MRSA detection from the clinical sample preparation to susceptibility result was less than 2 h. In contrast, the conventional susceptibility testing, which includes the use of the automated Vitek 2 system, requires at least 24 h, including 18-24 h for isolating and purifying bacteria from the clinical samples, and an additional 7 h for conducting susceptibility testing. Ultimately, a novel method for rapid and direct MRSA analysis has been created by combining split DNAzyme based signal recycling and ABTS based color reaction. Due to its short reaction time and convenience, this aptamer-based colorimetric assay should be a useful tool for more rapid and accurate detection of MRSA in clinical specimens.
Supplemental Materials
Author Contributions
Z.W. is the supervisor of the team in all research steps including data gathering, data analysis. J.X. and D.J., as the co-first author, has the main role for experimental data collection. All authors have read and approved the manuscript.
Conflict of Interest
The authors have no financial conflicts of interest to declare.
References
- Callejo-Torre F, Eiros Bouza JM, Olaechea Astigarraga P, Coma Del Corral MJ, Palomar Martinez M, Alvarez-Lerma F,
et al . 2016. Risk factors for methicillin-resistantStaphylococcus aureus colonisation or infection in intensive care units and their reliability for predicting MRSA on ICU admission.Infez. Med. 24 : 201-209. - David MZ, Daum RS. 2010. Community-associated methicillin-resistant
Staphylococcus aureus : epidemiology and clinical consequences of an emerging epidemic.Clin. Microbiol. Rev. 23 : 616-687. - Bassetti M, Labate L, Melchio M, Robba C, Battaglini D, Ball L,
et al . 2022. Current pharmacotherapy for methicillin-resistantStaphylococcus aureus (MRSA) pneumonia.Expert Opin. Pharmacother. 23 : 361-375. - Burnham CD, Leeds J, Nordmann P, O'Grady J, Patel J. 2017. Diagnosing antimicrobial resistance.
Nat. Rev. Microbiol. 15 : 697-703. - Dangerfield B, Chung A, Webb B, Seville MT. 2014. Predictive value of methicillin-resistant
Staphylococcus aureus (MRSA) nasal swab PCR assay for MRSA pneumonia.Antimicrob. Agents Chemother. 58 : 859-864. - Lakhundi S, Zhang K. 2018. Methicillin-resistant
Staphylococcus aureus : Molecular characterization, evolution, and epidemiology.Clin. Microbiol. Rev. 31 : e00020-18. - Lee AS, de Lencastre H, Garau J, Kluytmans J, Malhotra-Kumar S, Peschel A,
et al . 2018. Methicillin-resistantStaphylococcus aureus .Nat. Rev. Dis. Primers. 4 : 18033. - Xu L, Liang W, Wen Y, Wang L, Yang X, Ren S,
et al . 2018. An ultrasensitive electrochemical biosensor for the detection of mecA gene in methicillin-resistantStaphylococcus aureus .Biosens. Bioelectron. 99 : 424-430. - Yang H, Chen H, Cao L, Wang H, Deng W, Tan Y,
et al . 2020. An immunosensor for sensitive photoelectrochemical detection ofStaphylococcus aureus using ZnS-Ag(2)S/polydopamine as photoelectric material and Cu2O as peroxidase mimic tag.Talanta 212 : 120797. - Zheng L, Shen Y, Dong W, Zheng C, Zhou R, Lou YL. 2021. Rapid detection and antimicrobial susceptibility testing of pathogens using AgNPs-invertase complexes and the personal glucose meter.
Front. Bioeng. Biotechnol. 9 : 795415. - Yadav MK, Kwon SK, Huh HJ, Chae SW, Song JJ. 2012. Detection of methicillin-resistant
Staphylococcus aureus (MRSA) from nasal samples by multiplex real-time PCR based on dual priming AT-rich primers.Folia Microbiol. (Praha) 57 : 37-45. - Gao Y, Fan X, Zhang X, Guan Q, Xing Y, Song W. 2023. HCR/DNAzyme-triggered cascaded feedback cycle amplification for selfpowered dual-photoelectrode detection of femtomolar HPV16.
Biosens. Bioelectron. 237 : 115483. - Pan J, Bao D, Bao E, Chen J. 2021. A hairpin probe-mediated DNA circuit for the detection of the
mecA gene ofStaphylococcus aureus based on exonuclease III and DNAzyme-mediated signal amplification.Analyst 146 : 3673-3678. - Wang JC, Tung YC, Ichiki K, Sakamoto H, Yang TH, Suye SI,
et al . 2020. Culture-free detection of methicillin-resistantStaphylococcus aureus by using self-driving diffusometric DNA nanosensors.Biosens. Bioelectron. 148 : 111817. - Zhao X, Luo C, Mei Q, Zhang H, Zhang W, Su D,
et al . 2020. Aptamer-cholesterol-mediated proximity ligation assay for accurate identification of exosomes.Anal. Chem. 92 : 5411-5418. - Wei L, Wang Z, Wang J, Wang X, Chen Y. 2022. Aptamer-based colorimetric detection of methicillin-resistant
Staphylococcus aureus by using a CRISPR/Cas12a system and recombinase polymerase amplification.Anal. Chim. Acta 1230 : 340357. - Xu L, Dai Q, Shi Z, Liu X, Gao L, Wang Z,
et al . 2020. Accurate MRSA identification through dual-functional aptamer and CRISPRCas12a assisted rolling circle amplification.J. Microbiol. Methods 173 : 105917. - Huang Z, Yu X, Yang Q, Zhao Y, Wu W. 2021. Aptasensors for
Staphylococcus aureus risk assessment in food.Front. Microbiol. 12 : 714265. - Li D, Liu L, Huang Q, Tong T, Zhou Y, Li Z,
et al . 2021. Recent advances on aptamer-based biosensors for detection of pathogenic bacteria.World J. Microbiol. Biotechnol. 37 : 45. - Wang Y, Wang Z, Zhan Z, Liu J, Deng T, Xu H. 2022. Fluorescence detection of
Staphylococcus aureus using vancomycin functionalized magnetic beads combined with rolling circle amplification in fruit juice.Anal. Chim. Acta 1189 : 339213. - Li Q, Zhou D, Pan J, Liu Z, Chen J. 2018. Ultrasensitive and simple fluorescence biosensor for detection of the
mecA gene ofStaphylococcus aureus by using an exonuclease III-assisted cascade signal amplification strategy.Analyst 143 : 5670-5675. - Ocsoy I, Yusufbeyoglu S, Yilmaz V, McLamore ES, Ildiz N, Ulgen A. 2017. DNA aptamer functionalized gold nanostructures for molecular recognition and photothermal inactivation of methicillin-resistant
Staphylococcus aureus .Colloids Surf. B. Biointerfaces 159 : 16-22. - Li R, Liu Q, Jin Y, Li B. 2020. Sensitive colorimetric determination of microRNA let-7a through rolling circle amplification and a peroxidase-mimicking system composed of trimeric G-triplex and hemin DNAzyme.
Mikrochim. Acta 187 : 139. - Alamer S, Eissa S, Chinnappan R, Zourob M. 2018. A rapid colorimetric immunoassay for the detection of pathogenic bacteria on poultry processing plants using cotton swabs and nanobeads.
Mikrochim. Acta 185 : 164.
Related articles in JMB
Article
Research article
J. Microbiol. Biotechnol. 2024; 34(6): 1322-1327
Published online June 28, 2024 https://doi.org/10.4014/jmb.2404.04012
Copyright © The Korean Society for Microbiology and Biotechnology.
Target Recognition Triggered Split DNAzyme based Colorimetric Assay for Direct and Sensitive Methicillin-Resistance Analysis of Staphylococcus aureus
Jin Xu†, Dandan Jin†, and Zhengwei Wang*
Department of Anesthesiology, People’s Hospital of Chongqing Liang Jiang New Area, Chongqing 401121, P.R. China
Correspondence to:Zhengwei Wang, 13996082144@163.com
†These authors contributed equally to this work.
Abstract
The accurate and rapid detection of methicillin-resistant Staphylococcus aureus (MRSA) holds significant clinical importance. This work presents a new method for detecting methicillin-resistant Staphylococcus aureus (S. aureus) in clinical samples. The method uses an aptamer-based colorimetric assay that combines a recognizing probe to identify the target and split DNAzyme to amplify the signal, resulting in a highly sensitive and direct analysis of methicillin-resistance. The identification of the PBP2a protein on the membrane of S. aureus in clinical samples leads to the allosterism of the recognizing probe, and thus provides a template for the proximity ligation of split DNAzyme. The proximity ligation of split DNAzyme forms an intact DNAzyme to identify the loop section in the L probe and generates a nicking site to release the loop sequence (“3” and “4” fragments). The “3” and “4” fragments forms an intact sequence to induce the catalytic hairpin assembly, exposing the G-rich section. The released the G-rich sequence of LR probe induces the formation of G-quadruplex–hemin DNAzyme as a colorimetric signal readout. The absorption intensity demonstrated a strong linear association with the logarithm of the S. aureus concentration across a wide range of 5 orders of magnitude dynamic range under the optimized experimental parameters. The limit of detection was calculated to be 23 CFU/ml and the method showed high selectivity for MRSA.
Keywords: MRSA, aptamer, split DNAzyme, G-quadruplex
Introduction
The infection in patients undergoing surgical treatment is mostly a nosocomial infection caused by bacteria, which not only exacerbates the patient’s suffering during treatment but also poses a significant cost burden.
The rapid and precise diagnosis of methicillin-resistant
Aptamers, referred to as chemical antibodies, are single-stranded DNA or RNA molecules that exhibit a strong and particular binding affinity for a diverse array of molecule [15]. These aptamers have found extensive application in the detection of the PBP2a protein, owing to their exceptional specificity and affinity towards the target molecules [16, 17]. Aptamers, in comparison to typical antibodies, exhibit greater stability and are more readily prepared and modified [18, 19]. This renders them viable substitutes for antibodies as recognition agents in
In the current study, an aptamer-based colorimetric biosensor was developed for the rapid, ultrasensitive, and visual detection of MRSA using recognizing probe and the split DNAzyme system. In this sensing strategy, an aptamer, which is integrated in the recognizing probe with loop-stem structure, was employed to specifically bind with PBP2a protein on the surface of
-
Figure 1. The working mechanism of the proposed method for direct methicillin resistance analysis.
Materials and Methods
The sequences used in this method were synthesized and purified by Sangon Biotech (China). The detail of the sequences used in this research is shown in Table S1. The bacteria, including the methicillin-resistant
Detection Procedure of the Method
300 nM of the recognizing probe (10 μl) and various concentrations of MRSA (10 μl) were mixed in a tube containing 30 μl of PBS buffer. The mixture was incubated at room temperature for 30 min, followed by the mixing with the L probe@plate. Afterwards, 10 μL of the s1 and s2 sequences (100 nM, respectively) were added to the plate. The mixture was incubated at room temperature for 30 min. afterwards, the liquid supernatant was removed from the plate well, and the plate was washed for 3 times with PBS buffer solution. 10 μl of the LC and LR probe (100 nM, respectively), 20 μl of PBS buffer solution were added to the palte for the color reaction. Finally, 1 μl of hemin (20 μM, prepared in DMSO), 9 μl of 10 × HEPES (250 mM HEPES, 2 M NaCl, 100 mM KCl, and 0.5%Triton X-100, pH 5.2), and a sufficient amount of H2O were added to form a resultant solution of 90 μl, and then incubated for 30 min at 37°C. UV-vis absorption spectra were recorded at a fixed reaction time of 10 min after the addition of 10 μl of 4 mM ABTS2– and 10 μl of 400 mM H2O2 to the solutions.
Results and Discussion
Assembly of Recognizing Probe and Feasibility Analysis
A fluorescent assay was conducted to determine if the developed recognizing probe could selectively identify the target bacterium and subsequently mediate the proximity ligation of split DNAzyme. Fig. 2A demonstrates that the fluorescence intensity at 510 nm of the recognizing probe (R probe) was noticeably greater when incubated with the target compared to probes without the target. This indicates that the presence of bacteria can trigger the allosterism of the recognizing probe. To investigate the potential unfolding of a recognizing probe, various interfering molecules, including exosomes, protein A, MSSA (methicillin-sensitive
-
Figure 2. Feasibility analysis of the proposed method.
(A) Fluorescence spectrum of the FAM labeled recognizing probe when MRSA exists or not. (B) Fluorescence intensities of the recognizing probe for target and interfering molecules detection. (C) Fluorescence intensities of the recognizing probe under different experimental conditions. (D) Fluorescence spectrum of the FAM labeled split DNAzyme before and after proximity ligation of split DNAzyme. (E) Fluorescence intensities of the FAM labeled LR probe during the catalytic hairpin assembly process. (F) Absorbance of the approach during MRSA detection. Inserted is the visible absorbance changes.
n = 3 technical duplicates.
Experimental Parameter Optimization
Prior to assessing the detection performance, we refined the experimental parameters of the approach, such as the concentration of the recognizing probe, the ratio of LC and LR probes, and the duration of the reactions. The Atarget/Ablank, which is the ratio of the absorbance when target existed (Atarget) or not (Ablank), is used to compare the detection performance of the method. In the studies examining the concentration of recognizing probes, the absorbance values obtained showed a gradual increase as the concentration of recognizing probes increased from 50 to 200 nM. However, no further increase in absorbance values was found at higher concentrations (Fig. 3A). Thus, the concentration of the recognizing probes was determined to be 200 nM. Furthermore, the proportion of LC and LR probes and the duration of the reaction were established as 1:1 (Fig. 3B) and 90 min (Fig. 3C), respectively.
-
Figure 3. Optimization of experimental parameters.
Absorbance ratio of the approach when detecting MRSA with different R probe concentrations (A) concentration ratio of LC and LR probes (B) reaction time (C).
n = 3 technical duplicates.
Sensitive and Selectivity Detection of Methicillin Resistance S. aureus
The suggested colorimetric method was used to detect various quantities of MRSA N315 in PBS under optimized experimental conditions. To evaluate the capability of the established method for sensitive detection of MRSA, a range of target concentrations were prepared and examined. Fig. 4A displays the UV-vis absorption signals for different concentrations of the target. The absorbance consistently increased as the target concentrations ranged from 50 CFU/ml to 106 CFU/ml. Fig. 4B illustrates the linear relationship between the absorption intensities and the logarithm of the target concentration. The range of concentrations considered is from 50 CFU/ml to 106 CFU/ml. The linear correlation coefficient for this relationship is 0.9932. Based on the 3σ rule, the estimated detection limit is 23 CFU/ml, which above the detection limit of current approaches.
-
Figure 4. Analytical performance of the method.
(A) Absorbance ratio of the approach when detecting MRSA with different concentrations. (B) Correlation between the absorbance ratio and the concentration of MRSA. (C) Absorbance of the approach when detecting MRSA and interfering bacteria.
n = 3 technical duplicates. (D) Absorbance of the approach when detecting MRSA from 10 sample duplicates.
The detection performance of a biosensor’s performance relies heavily on its selectivity. We employed three interfering bacteria to examine the discerning detection capability of the approach. The absorption intensities can clearly be distinguished of MRSA from MSSA,
Analytical Performance of the Approach
Target bacterial strains and MSSA strains were analyzed by colony counting method and the proposed method to evaluate the detection effect. The colony counting test results showed that 10 samples contained bacteria with methicillin resistance, which proved that 7 strains were MRSA, 3 strains were MSSA. The results of the proposed detection system also show the same result in all strains of bacteria such as 7 strains detected as MRSA, 3 strains were MSSA (Fig. 5A). The stability of the proposed method was assessed using 10% commercial whole blood supplemented with bacteria. As illustrated in Fig. 5B, by comparing the characteristic peak values, the recovery rates of the MRSA concentration calculated by the method ranged from 98.78% to 102.3%, indicating a high stability of the method in complicated experimental conditions.
-
Figure 5. Clinical application of the method.
(A) MRSA positive sample reported by the method and colony counting method. (B) MRSA concentration calculated by the method from samples added with different concentrations of MRSA.
Conclusion
In this study, an aptamer-based colorimetric assay for MRSA detection was constructed based on the high affinity of aptamer to target protein PBP2a. In this method, the PBP2a protein aptamer is integrated in a recognizing probe with a hairpin structure. the specific target recognition leads to the allosterism of the recognizing probe, which provides a template for the proximity ligation of DNAzyme. The assembled DNAzyme cleaves the L probe on plate to induce subsequent signal amplification and color reaction. Eventually, the method exhibits a low limit of detection of 23 CFU/ml and high specificity towards MRSA compared to MSSA with potentials for rapid detection of MRSA in real clinical specimens, such as plasma. In addition, the total time of the method for MRSA detection from the clinical sample preparation to susceptibility result was less than 2 h. In contrast, the conventional susceptibility testing, which includes the use of the automated Vitek 2 system, requires at least 24 h, including 18-24 h for isolating and purifying bacteria from the clinical samples, and an additional 7 h for conducting susceptibility testing. Ultimately, a novel method for rapid and direct MRSA analysis has been created by combining split DNAzyme based signal recycling and ABTS based color reaction. Due to its short reaction time and convenience, this aptamer-based colorimetric assay should be a useful tool for more rapid and accurate detection of MRSA in clinical specimens.
Supplemental Materials
Author Contributions
Z.W. is the supervisor of the team in all research steps including data gathering, data analysis. J.X. and D.J., as the co-first author, has the main role for experimental data collection. All authors have read and approved the manuscript.
Conflict of Interest
The authors have no financial conflicts of interest to declare.
Fig 1.
Fig 2.
Fig 3.
Fig 4.
Fig 5.
References
- Callejo-Torre F, Eiros Bouza JM, Olaechea Astigarraga P, Coma Del Corral MJ, Palomar Martinez M, Alvarez-Lerma F,
et al . 2016. Risk factors for methicillin-resistantStaphylococcus aureus colonisation or infection in intensive care units and their reliability for predicting MRSA on ICU admission.Infez. Med. 24 : 201-209. - David MZ, Daum RS. 2010. Community-associated methicillin-resistant
Staphylococcus aureus : epidemiology and clinical consequences of an emerging epidemic.Clin. Microbiol. Rev. 23 : 616-687. - Bassetti M, Labate L, Melchio M, Robba C, Battaglini D, Ball L,
et al . 2022. Current pharmacotherapy for methicillin-resistantStaphylococcus aureus (MRSA) pneumonia.Expert Opin. Pharmacother. 23 : 361-375. - Burnham CD, Leeds J, Nordmann P, O'Grady J, Patel J. 2017. Diagnosing antimicrobial resistance.
Nat. Rev. Microbiol. 15 : 697-703. - Dangerfield B, Chung A, Webb B, Seville MT. 2014. Predictive value of methicillin-resistant
Staphylococcus aureus (MRSA) nasal swab PCR assay for MRSA pneumonia.Antimicrob. Agents Chemother. 58 : 859-864. - Lakhundi S, Zhang K. 2018. Methicillin-resistant
Staphylococcus aureus : Molecular characterization, evolution, and epidemiology.Clin. Microbiol. Rev. 31 : e00020-18. - Lee AS, de Lencastre H, Garau J, Kluytmans J, Malhotra-Kumar S, Peschel A,
et al . 2018. Methicillin-resistantStaphylococcus aureus .Nat. Rev. Dis. Primers. 4 : 18033. - Xu L, Liang W, Wen Y, Wang L, Yang X, Ren S,
et al . 2018. An ultrasensitive electrochemical biosensor for the detection of mecA gene in methicillin-resistantStaphylococcus aureus .Biosens. Bioelectron. 99 : 424-430. - Yang H, Chen H, Cao L, Wang H, Deng W, Tan Y,
et al . 2020. An immunosensor for sensitive photoelectrochemical detection ofStaphylococcus aureus using ZnS-Ag(2)S/polydopamine as photoelectric material and Cu2O as peroxidase mimic tag.Talanta 212 : 120797. - Zheng L, Shen Y, Dong W, Zheng C, Zhou R, Lou YL. 2021. Rapid detection and antimicrobial susceptibility testing of pathogens using AgNPs-invertase complexes and the personal glucose meter.
Front. Bioeng. Biotechnol. 9 : 795415. - Yadav MK, Kwon SK, Huh HJ, Chae SW, Song JJ. 2012. Detection of methicillin-resistant
Staphylococcus aureus (MRSA) from nasal samples by multiplex real-time PCR based on dual priming AT-rich primers.Folia Microbiol. (Praha) 57 : 37-45. - Gao Y, Fan X, Zhang X, Guan Q, Xing Y, Song W. 2023. HCR/DNAzyme-triggered cascaded feedback cycle amplification for selfpowered dual-photoelectrode detection of femtomolar HPV16.
Biosens. Bioelectron. 237 : 115483. - Pan J, Bao D, Bao E, Chen J. 2021. A hairpin probe-mediated DNA circuit for the detection of the
mecA gene ofStaphylococcus aureus based on exonuclease III and DNAzyme-mediated signal amplification.Analyst 146 : 3673-3678. - Wang JC, Tung YC, Ichiki K, Sakamoto H, Yang TH, Suye SI,
et al . 2020. Culture-free detection of methicillin-resistantStaphylococcus aureus by using self-driving diffusometric DNA nanosensors.Biosens. Bioelectron. 148 : 111817. - Zhao X, Luo C, Mei Q, Zhang H, Zhang W, Su D,
et al . 2020. Aptamer-cholesterol-mediated proximity ligation assay for accurate identification of exosomes.Anal. Chem. 92 : 5411-5418. - Wei L, Wang Z, Wang J, Wang X, Chen Y. 2022. Aptamer-based colorimetric detection of methicillin-resistant
Staphylococcus aureus by using a CRISPR/Cas12a system and recombinase polymerase amplification.Anal. Chim. Acta 1230 : 340357. - Xu L, Dai Q, Shi Z, Liu X, Gao L, Wang Z,
et al . 2020. Accurate MRSA identification through dual-functional aptamer and CRISPRCas12a assisted rolling circle amplification.J. Microbiol. Methods 173 : 105917. - Huang Z, Yu X, Yang Q, Zhao Y, Wu W. 2021. Aptasensors for
Staphylococcus aureus risk assessment in food.Front. Microbiol. 12 : 714265. - Li D, Liu L, Huang Q, Tong T, Zhou Y, Li Z,
et al . 2021. Recent advances on aptamer-based biosensors for detection of pathogenic bacteria.World J. Microbiol. Biotechnol. 37 : 45. - Wang Y, Wang Z, Zhan Z, Liu J, Deng T, Xu H. 2022. Fluorescence detection of
Staphylococcus aureus using vancomycin functionalized magnetic beads combined with rolling circle amplification in fruit juice.Anal. Chim. Acta 1189 : 339213. - Li Q, Zhou D, Pan J, Liu Z, Chen J. 2018. Ultrasensitive and simple fluorescence biosensor for detection of the
mecA gene ofStaphylococcus aureus by using an exonuclease III-assisted cascade signal amplification strategy.Analyst 143 : 5670-5675. - Ocsoy I, Yusufbeyoglu S, Yilmaz V, McLamore ES, Ildiz N, Ulgen A. 2017. DNA aptamer functionalized gold nanostructures for molecular recognition and photothermal inactivation of methicillin-resistant
Staphylococcus aureus .Colloids Surf. B. Biointerfaces 159 : 16-22. - Li R, Liu Q, Jin Y, Li B. 2020. Sensitive colorimetric determination of microRNA let-7a through rolling circle amplification and a peroxidase-mimicking system composed of trimeric G-triplex and hemin DNAzyme.
Mikrochim. Acta 187 : 139. - Alamer S, Eissa S, Chinnappan R, Zourob M. 2018. A rapid colorimetric immunoassay for the detection of pathogenic bacteria on poultry processing plants using cotton swabs and nanobeads.
Mikrochim. Acta 185 : 164.