Articles Service
Effect of Distribution System Materials and Water Quality on Heterotrophic Plate Counts and Biofilm Proliferation
Civil and Environmental Engineering Dept. University of Central Florida P.O. Box 162450 Orlando Florida 32816-2450 U.S.A., 1Division of Waste Seoul Metropolitan Government Institute of Health and Environment Seoul 137-130 Korea
J. Microbiol. Biotechnol. 2004; 14(6): 1114-1119
Published December 28, 2004
Copyright © The Korean Society for Microbiology and Biotechnology.
Abstract
Keywords
Related articles in JMB
Article
J. Microbiol. Biotechnol. 2004; 14(6): 1114-1119
Published online December 28, 2004
Copyright © The Korean Society for Microbiology and Biotechnology.
Effect of Distribution System Materials and Water Quality on Heterotrophic Plate Counts and Biofilm Proliferation
Young Cheol Chang and Kweon Jung 1*
Civil and Environmental Engineering Dept. University of Central Florida P.O. Box 162450 Orlando Florida 32816-2450 U.S.A., 1Division of Waste Seoul Metropolitan Government Institute of Health and Environment Seoul 137-130 Korea
Abstract
The biofilms on pipe walls in water distribution systems are of interest since they can lead to chlorine demand, coliform growth, pipe corrosion, and water taste and odor problems. As such, the study described in this paper is part of an AWWARF and Tampa Bay Water tailored collaboration project to determine the effect of blending different source waters on the water quality in various distribution systems. The project was based on 18 independent pilot distribution systems (PDS), each being fed by a different water blend (7 finished waters blended in different proportions). The source waters compared were groundwater, surface water, and brackish water, which were treated in a variety of pilot distribution systems, including reverse osmosis (RO) (desalination), both membrane and chemical softening, and ozonation-biological activated carbon (BAC), resulting in a total of 7 different finished waters. The observations from this study consistently demonstrated that unlined ductile iron was more heavily colonized by a biomass than galvanized steel, lined ductile iron, and PVC (in that order) and that the fixed biomass accumulation was more influenced by the nature of the supporting material than by the water quality (including the secondary residual levels). However, although the bulk liquid water cultivable bacterial counts (i.e. heterotrophic plate counts or HPCs) did not increase with a greater biofilm accumulation, the results also suggested that high HPCs corresponded to a low disinfectant residual more than a high biofilm inventory. Furthermore, temperature was found to affect the biofilms, plus the AOC was important when the residual was between 0.6 and 2.0 mg
Keywords: Pipematerial, biofilmbiomassquantification, drinkingwater, PEPA